Product 02 / 08

HDI PCB

Laser-drilled blind and buried vias, via fill and fine-line imaging for boards that have run out of room. 1st-order HDI in volume, 3rd-order supported after stack-up review.

HDI PCB poster showing stack-up, impedance tolerance, 2/2 mil inner traces and 0.20 mm minimum hole

Reference build · HDI, 1st to 3rd order · click the sheet to enlarge · dimensions in mm unless noted.

Overview

What this family is for

HDI is a density decision, not a fashion. When the package pitch and the number of nets stop fitting on a conventional board, build-up layers and laser vias buy back the space. We quote the stack-up you need and say plainly which order is production-proven and which one has to be reviewed.

  • Laser drilling, plasma desmear and copper via fill for stacked microvias.
  • 2/2 mil inner-layer lines, 3/3 mil outer, 0.075 mm layer-to-layer registration.
  • 1st-order HDI in volume production; 2nd and 3rd-order stacks supported after design review.
  • Impedance held to ±8% where the design leaves no margin.

Production window

HDI PCB · production limits
ParameterCapability
Build-up1st-order HDI in volume; 2nd and 3rd-order by review
Layer count1–48 layers including build-up layers
MicroviaLaser drilled, 0.10 mm and above
Via fillCopper-filled, planarised for stacked vias
Min inner trace / space2/2 mil (0.05 mm)
Min outer trace / space3/3 mil (0.075 mm)
Min drilled hole0.20 mm
Aspect ratio10:1
Impedance control±10% standard, ±8% on request
Max panel size580 × 900 mm

Materials, finishes and where it is used

Materials

High-Tg FR4 build-up laminateBT resin for high-reliability buildsRCC and prepreg bond films matched to the stackHalogen-free options

Surface finishes

ENIGENEPIG for wire bondingOSPImmersion silverSelective hard gold

Typical applications

  • Smartphones, wearables and handheld terminals
  • Camera and sensor modules
  • Optical and RF modules
  • Medical imaging front ends

Questions buyers ask about this family

Engineering FAQ
Is 3rd-order HDI really in production?1st-order HDI runs in volume without special approval, and stacks up to 3rd-order HDI are supported. Each 2nd or 3rd-order build is reviewed against your layer build, via pitch and yield expectation before we commit to a price and a date. We will tell you if the stack is beyond what we can hold reliably.
Can you fill and plate over vias?Yes — copper-filled and planarised vias for stacked microvias and via-in-pad, followed by planarisation so the pad stays flat for assembly.
Do you provide impedance reports?On controlled-impedance designs we measure coupons with TDR and ship the report with the lot, not on request afterwards.

Quotation

Quote a HDI PCB build.

Send the Gerber, drill file and target quantity. You get a DFM note, a panel count and a dated price within 24 hours.

WhatsApp